Coriolis flow meter for nitrogen

Gas and liquid phase

Nitrogen comes in two forms: gas under pressure and liquid at -196 °C. These are different tasks and different meter executions.

Open configurator Request a quote
DN08-DN80up to 120,000 kg/h-196...+150 °Cup to 10 MPa±0.5-1.0% of gas
Cryogenic sensors Mass-EXPERT
Cryogenic sensors Mass-EXPERT

What happens with nitrogen

Gaseous nitrogen density is 1.25 kg/m³ at standard conditions. Pressure and pressure drop matter, not viscosity.

Liquid nitrogen boils at -196 °C and is stored in cryogenic tanks. This needs execution L, U or Δ tubes and DN08-DN80.

On evaporation the flow becomes two-phase. The sensor goes where back pressure is maintained and there are no dead legs.

Typical points and sizes

Typical points and sizes
PointFlow, kg/hDNExecution
Gas lines1,000-30,000DN25-DN80T
Liquid nitrogen100-10,000DN15-DN50L
Reactor dosing50-1,000DN04-DN15T
Cryogenic refuelling500-5,000DN15-DN40L
100 - 30 000 кг/чDN01DN08DN15DN25DN50DN80DN150DN250
Meter range by DN and typical band for nitrogen. 100-30 000 кг/ч, логарифмическая шкала.

What to check before ordering

  1. Phase: gas or liquid.
  2. Temperature and cryogenic execution.
  3. Pressure and back pressure.
  4. Dew point and condensate.
  5. Ex if flammable gases are nearby.

Liquid nitrogen

Liquid nitrogen requires execution L: -196 to +150 °C, up to 4 MPa, U or Δ tubes, DN08-DN80. Materials and seals are selected for cryogenic temperatures.

When Coriolis is not needed

For simple gas supply without mass accounting a rotameter or differential pressure device will do. Coriolis is used for mass and cryogenic tasks.

Frequent questions

Can liquid nitrogen be measured?

Yes, in execution L down to -196 °C.

What gas accuracy?

±0.5-1.0% depending on size.

What about evaporation?

Two-phase flow distorts measurement. Back pressure and no dead legs are required.

Is Ex required?

Nitrogen is not flammable, but Ex is discussed if flammable gases are nearby.