CO2 is stored as a liquid under pressure. Once pressure drops below equilibrium, part turns to gas and dry ice forms, so the meter goes upstream of the regulator.
Liquid CO2 at 20 °C exists above 1.5-2.0 MPa depending on purity and temperature. Density is 770-1000 kg/m³. On expansion part of the liquid boils, temperature falls and dry ice may form.
Dry ice clogs the sensor and valves. The meter therefore goes where pressure is above equilibrium, and the regulator and safety valves are downstream.
For beverage filling and carbonation the mass of CO2 matters, not volume: density in the cylinder and in the line differ.
| Point | Flow, kg/h | DN | Execution |
|---|---|---|---|
| Carbonation | 100-3,000 | DN08-DN25 | T |
| Cylinder filling | 1,000-10,000 | DN25-DN40 | T |
| Truck loading | 5,000-30,000 | DN40-DN50 | T |
| Reactor dosing | 50-1,000 | DN04-DN15 | T |
In the liquid phase the meter measures mass and density steadily. If the flow after the regulator is two-phase, readings will drift: this is physics, not a meter fault.
For food-grade CO2, Tri-Clamp connections and the straight-tube sensor L are available; they are easier to clean and purge.
If only total gas volume at the outlet is needed, a gas meter is simpler. Coriolis is used in the liquid phase and where accurate mass flow matters.
Downstream pressure drops and CO2 flashes. In two-phase flow mass is calculated with an error.
Yes, gas accuracy is ±0.5-1.0%. Process lines usually need the liquid phase.
It forms on expansion and clogs the sensor. Back pressure, heating and no dead legs help.
Tri-Clamp and straight-tube L for food lines; flanges and threads for industrial lines.