Application by medium

Coriolis flow meter for diesel fuel

Loading, filling stations, boiler house

Diesel is accounted in tonnes and sold in litres. Conversion goes through density at 15 °C, and a mass meter gives both mass and density in line.

Open configurator Request a quote
DN08-DN80up to 120,000 kg/h-40...+150 °Cup to 10 MPa±0.1% of mass
T execution flow meters
T execution flow meters

What happens with diesel

Summer diesel density is about 835-860 kg/m³, winter 820-840 kg/m³ at 15 °C. Tonnes to litres conversion depends on density, so density is needed at the moment of metering, not from the batch certificate.

Diesel has very low conductivity. A magnetic meter does not work on it, and volumetric meters require density and temperature corrections.

In winter viscosity rises and paraffin may settle. The meter and piping are selected with heating and filtration in mind.

Typical points and sizes

Typical points and sizes
PointFlow, kg/hDNExecution
Truck loading20,000-60,000DN50-DN80T
Fuel dispenser5,000-15,000DN25-DN40T
Additive dosing50-1,000DN04-DN15T
Boiler house1,000-10,000DN15-DN40T
5 000 - 60 000 кг/чDN01DN08DN15DN25DN50DN80DN150DN250
Meter range by DN and typical band for diesel loading. 5 000-60 000 кг/ч, логарифмическая шкала.

What to check before ordering

  1. Winter mode: heating, insulation, pour point.
  2. Filter upstream so paraffin and dirt do not settle on the tubes.
  3. Earthing and Ex for hazardous areas.
  4. Drain: fuel must not stay in the housing.
  5. On-site verification with a compact prover or reference meter.

Mass and density instead of correction

The meter measures mass, density and temperature at the same time. Accounting is done in tonnes and the actual batch density is visible without manual entry or disputes about temperature corrections.

Custody transfer needs more than meter accuracy: straight runs, verification and documents. We supply both meters and complete metering units.

When Coriolis is not needed

If only volume at the dispenser matters and an approved density meter is available, a volumetric meter can work. For custody transfer and internal mass accounting Coriolis is more accurate and easier to verify.

Frequent questions

How to convert tonnes to litres?

Through density at 15 °C: volume = mass / density. The meter provides density in line, so conversion uses the actual batch.

Can it work in winter?

Yes, if fuel does not freeze in the line. The sensor handles -40 °C, but piping and filter need insulation.

Is Ex required?

It depends on the zone. Fuel depots and filling stations usually require it; Ex versions are available.

What to use for 60 t/h?

DN80 with 120,000 kg/h, 50% of span. DN50 at 60 t/h is already above its range.