Application by medium

Coriolis flow meter for formalin

Dosing and accounting

Formalin is toxic and requires a tight line. Flow and density control the supply, while personnel are protected from vapours.

Open configurator Request a quote
DN08-DN50up to 39,000 kg/h+5...+60 °Cup to 10 MPa±0.1-0.2%
Unit at a chemical plant
Unit at a chemical plant

What happens with formalin

Density of 37-40% formalin is about 1080 kg/m³. Density and temperature can indicate concentration if the solution is two-component.

Formalin is toxic and flammable under certain conditions. Tightness, ventilation and protection of electronics from vapours are required.

Polymerisation is possible on cooling. The line is kept within the working temperature range.

Typical points and sizes

Typical points and sizes
PointFlow, kg/hDNExecution
Dosing10-1,000DN04-DN15T
Transfer500-5,000DN15-DN40T
Loading1,000-10,000DN25-DN40T
Blending100-3,000DN08-DN25T
10 - 5 000 кг/чDN01DN08DN15DN25DN50DN80DN150DN250
Meter range by DN and typical band for formalin. 10-5 000 кг/ч, логарифмическая шкала.

What to check before ordering

  1. Toxicity and room ventilation.
  2. Joint tightness.
  3. Seal material.
  4. Temperature and polymerisation risk.
  5. Flushing and drain.

Materials

Not all seals suit formalin. Tube and gasket materials are agreed for concentration and temperature from the 316L, 904L, C4 and Hastelloy list.

When Coriolis is not needed

For simple supply a rotameter will do. Coriolis is used for mass and accurate dosing.

Frequent questions

Is formalin hazardous?

Yes, it is toxic. Tightness and ventilation are required.

Can concentration be calculated?

By density and temperature if the solution is two-component.

What about polymerisation?

Keep working temperature and avoid dead legs.

Which material?

Agreed by concentration and temperature.

Related pages

Size a meter for your medium

Tell us flow, pressure, temperature and DN. We will reply with a configuration and lead time.

Open configurator Request a quote
Наверх