Coriolis flow meter for crude oil and emulsion

Wellstream and metering units

Crude at the field is a mix of oil, water and associated gas. A mass meter measures mass and density, but water cut is not derived from density alone.

Open configurator Request a quote
DN25-DN100up to 180,000 kg/h-40...+150 °Cup to 45 MPa (P)±0.1-0.15%
P and PK high-pressure executions
P and PK high-pressure executions

What happens with crude

Sales crude density is usually 820-900 kg/m³, but in the wellstream it depends on water cut, gas content and temperature. Mass of the mixture remains a physical figure that can be presented.

Free gas at the inlet distorts tube vibration. If gas content is unstable, a gas separator goes upstream rather than a correction factor.

Field pressure is high. Execution P covers lines up to 45 MPa, PK up to 96 MPa for special cases. Standard T handles 10 MPa and is not suitable for such units.

Typical points and sizes

Typical points and sizes
PointFlow, kg/hDNExecution
Test separator20,000-120,000DN50-DN100P
Chemical dosing50-1,000DN04-DN15P
Metering unit50,000-150,000DN80-DN100P
High-pressure lines10,000-60,000DN25-DN50PK
20 000 - 150 000 кг/чDN01DN08DN15DN25DN50DN80DN150DN250
Meter range by DN and typical band for wellstream. 20 000-150 000 кг/ч, логарифмическая шкала.

What to check before ordering

  1. Gas content and availability of a gas separator.
  2. Working and maximum pressure: this defines P or PK.
  3. Water cut and its seasonal variation.
  4. Ex zone and gas group.
  5. Vibration from nearby pumps and compressors.

What the meter does not do

Mass-EXPERT measures mass, density, temperature and volume. Water cut is not calculated from density: this needs an approved method and knowledge of composition. If the task is water percentage, it is solved by a separate analyser or laboratory.

For custody transfer the meter is in the State Register No. 98506-26, verification to MP 98506-26 on site or on a prover.

When Coriolis is not needed

If only rough transfer control is needed, a simpler meter will do. For oil accounting and mixture mass, Coriolis is convenient because it needs neither density nor temperature corrections.

Frequent questions

Can water cut be calculated?

Not from density alone. Composition, temperature and an approved algorithm are needed. The meter provides density; the method decides the rest.

What pressure does it handle?

T up to 10 MPa, P up to 45 MPa, PK up to 96 MPa. Wellstream usually needs P.

What about gas in the flow?

Free gas distorts measurement. A gas separator and stable conditions are required.

Is Ex available?

Yes, ME100 and ME200 in Ex versions, group IIC, temperature classes T2-T6.