Steam is measured by mass, but it has low density and high velocity. Pressure drop and temperature stability matter more than meter accuracy.
Saturated steam density at 1 MPa is about 5 kg/m³; superheated steam is lower. Low density means high velocity and noticeable pressure drop.
Above +150 °C execution G is required up to +230 °C; superheated steam up to +350 °C needs C with remote electronics.
Condensate in the line distorts measurement. Drain, heating and no dead legs are required.
| Point | Flow, kg/h | DN | Execution |
|---|---|---|---|
| Saturated steam | 500-20,000 | DN40-DN80 | G |
| Superheated steam | 500-30,000 | DN40-DN100 | C |
| Process steam | 100-10,000 | DN25-DN80 | G |
| Own needs | 100-5,000 | DN25-DN50 | G |
G handles up to +230 °C; C up to +350 °C with mandatory remote installation and 3-30 m cable (up to 100 m). Saturated steam usually needs G.
Large steam flows often use vortex or differential pressure meters. Coriolis is used for mass on process lines and where density matters.
G up to +230 °C; superheated up to +350 °C needs C.
It is more noticeable on steam. DN is chosen by allowable drop.
Yes, condensate distorts measurement.
Yes, if back pressure is maintained and there is no condensate in the sensor.