Application by medium

Coriolis flow meter for beer and fermented beverages

Filling and transfer between shops

In beer, density, alcohol and dissolved CO2 change at the same time. A mass meter measures mass and density, so filling and transfers agree without recalculation.

Open configurator Request a quote
DN15-DN50up to 39,000 kg/h-10...+150 °Cup to 10 MPa±0.1% of mass
Straight-tube sensors
Straight-tube sensors

What happens with beer

Beer density is 1005-1015 kg/m³ and changes during fermentation. Mass remains a reliable figure for settlement and internal accounting.

Dissolved CO2 forms bubbles. If line pressure drops below equilibrium, gas is released and the flow becomes two-phase: readings drift. The meter goes where pressure stays above equilibrium.

Foam after filling and cleaning behaves like air in the line. Stable metering needs a rising run and gas release, not filtering of readings.

Typical points and sizes

Typical points and sizes
PointFlow, kg/hDNExecution
Filling2,000-20,000DN25-DN40T
Transfer between shops5,000-30,000DN40-DN50T
Syrup dosing100-1,000DN08-DN15T
Cleaning and water2,000-15,000DN25-DN40T
2 000 - 20 000 кг/чDN01DN08DN15DN25DN50DN80DN150DN250
Meter range by DN and typical band for beer filling. 2 000-20 000 кг/ч, логарифмическая шкала.

What to check before ordering

  1. Inlet pressure above equilibrium at working temperature.
  2. Vertical run upwards after the pump.
  3. No sharp reductions or dead pockets upstream.
  4. Cleaning at 80 °C and CIP: execution T, Tri-Clamp.
  5. Drain and foam release after cleaning.

Why not a magnetic meter

Beer conducts, but dissolved gas and foam cause errors even where conductivity is sufficient. Coriolis measures mass and density directly and is less sensitive to gas content than volumetric methods.

Filling needs the straight-tube sensor L: no bends, no pockets, easy cleaning, DN08-DN50, Tri-Clamp.

When Coriolis is not needed

A level gauge is enough for total volume in a tank. Coriolis is used where mass, density or component dosing is measured.

Frequent questions

Can it measure after carbonation?

Yes, if line pressure is above equilibrium and gas does not break out. Otherwise the flow is two-phase and mass is calculated with an error.

Which DN for 15 t/h?

DN40 handles 27,000 kg/h; 15 t/h is 55% of span, a normal working point.

Is verification required for internal accounting?

The meter is in the State Register No. 98506-26, verification procedure MP 98506-26. Periodic verification is enough for internal accounting.

What about foam at filling?

Foam is air. Use a rising run, gas release and a pause after cleaning. Damping does not solve the cause.