Application by medium

Coriolis flow meter for natural gas

Mass and volume at standard conditions

Gas is measured in cubic metres at standard conditions, but paid by mass and energy. The meter gives mass directly and converts volume using the entered density.

Open configurator Request a quote
DN25-DN100up to 180,000 kg/h-40...+100 °Cup to 10 MPa±0.5-1.0% of gas
Mass-EXPERT range, DN01-DN250
Mass-EXPERT range, DN01-DN250

What happens with gas

Natural gas density is 0.7-0.9 kg/m³. It is hundreds of times lower than liquids, so tube velocity is higher and pressure drop is more noticeable. Diameter is chosen by flow and allowable pressure drop, not by pipe size.

The meter measures mass and density, and calculates volume at standard conditions using the density entered at setup. Gas composition and compressibility are not measured: if composition changes, the method must account for it.

Gas accuracy is ±0.5-1.0% depending on size. For commercial metering this is better than most differential pressure devices at low flows.

Typical points and sizes

Typical points and sizes
PointFlow, kg/hDNExecution
Gas distribution, boiler500-10,000DN25-DN50T
Gas engine1,000-20,000DN40-DN80T
Metering skid5,000-50,000DN50-DN100T
Process gas500-30,000DN25-DN80T
500 - 50 000 кг/чDN01DN08DN15DN25DN50DN80DN150DN250
Meter range by DN and typical band for medium-pressure gas. 500-50 000 кг/ч, логарифмическая шкала.

What to check before ordering

  1. Allowable pressure drop at working flow.
  2. Compressor pulsation and damping options.
  3. Gas temperature and dew point: condensate must not reach the sensor.
  4. Gas composition: it defines standard density and the conversion method.
  5. Ex zone and gas group.

Mass and volume

Mass flow does not depend on pressure or temperature. Volume at standard conditions is calculated from the density entered at setup. If composition is stable, this is enough for process metering and supplier settlement.

For commercial metering at large flows, ultrasonic or differential pressure meters are common. Coriolis wins at small and medium flows where accuracy is needed and long straight runs are unavailable.

When Coriolis is not needed

Transmission pipelines, large diameters and low pressure are not its task: pressure drop and cost will be higher than ultrasonic. Coriolis is used on process and metering lines.

Frequent questions

What accuracy on gas?

±0.5-1.0% depending on size. Liquid accuracy is higher, up to ±0.1%.

Is gas composition needed?

Not for mass. For standard volume, density at standard conditions is entered at setup.

What about pressure drop?

It is more noticeable than on liquids. DN is chosen so the drop fits the unit limits.

Can it be installed outdoors?

The sensor handles -60...+350 °C; electronics -40...+55 °C in Ex. Outdoor versions are discussed for the climate.