Gas is measured in cubic metres at standard conditions, but paid by mass and energy. The meter gives mass directly and converts volume using the entered density.
Natural gas density is 0.7-0.9 kg/m³. It is hundreds of times lower than liquids, so tube velocity is higher and pressure drop is more noticeable. Diameter is chosen by flow and allowable pressure drop, not by pipe size.
The meter measures mass and density, and calculates volume at standard conditions using the density entered at setup. Gas composition and compressibility are not measured: if composition changes, the method must account for it.
Gas accuracy is ±0.5-1.0% depending on size. For commercial metering this is better than most differential pressure devices at low flows.
| Point | Flow, kg/h | DN | Execution |
|---|---|---|---|
| Gas distribution, boiler | 500-10,000 | DN25-DN50 | T |
| Gas engine | 1,000-20,000 | DN40-DN80 | T |
| Metering skid | 5,000-50,000 | DN50-DN100 | T |
| Process gas | 500-30,000 | DN25-DN80 | T |
Mass flow does not depend on pressure or temperature. Volume at standard conditions is calculated from the density entered at setup. If composition is stable, this is enough for process metering and supplier settlement.
For commercial metering at large flows, ultrasonic or differential pressure meters are common. Coriolis wins at small and medium flows where accuracy is needed and long straight runs are unavailable.
Transmission pipelines, large diameters and low pressure are not its task: pressure drop and cost will be higher than ultrasonic. Coriolis is used on process and metering lines.
±0.5-1.0% depending on size. Liquid accuracy is higher, up to ±0.1%.
Not for mass. For standard volume, density at standard conditions is entered at setup.
It is more noticeable than on liquids. DN is chosen so the drop fits the unit limits.
The sensor handles -60...+350 °C; electronics -40...+55 °C in Ex. Outdoor versions are discussed for the climate.
Tell us flow, pressure, temperature and DN. We will reply with a configuration and lead time.
Open configurator Request a quoteWe will contact you shortly.
To attach a completed questionnaire, please email it to mass-expert@ame-info.ru.