Coriolis flow meter for sulphuric acid

Dosing and dilution

With sulphuric acid you choose the material first and the meter second. 98% acid density is 1830-1840 kg/m³, which helps control concentration in line.

Open configurator Request a quote
DN15-DN50up to 39,000 kg/h+10...+120 °Cup to 10 MPa±0.1-0.2%
Unit at a chemical plant
Unit at a chemical plant

What happens with sulphuric acid

Concentrated 98% acid has a density of 1830-1840 kg/m³; a diluted 20-30% solution is about 1140-1220 kg/m³. Density depends strongly on concentration, so it can be used to control dilution when temperature is known.

The acid is aggressive and there is no universal material. 316L suits diluted solutions at moderate temperature, but not hot concentrated acid. For 93-98% the material is selected by concentration and temperature.

Water ingress into concentrated acid changes both concentration and corrosion rate. Piping and drain are arranged so the line does not keep residues.

Typical points and sizes

Typical points and sizes
PointFlow, kg/hDNExecution
Reactor dosing100-3,000DN08-DN25T
Dilution1,000-10,000DN25-DN40T
Truck loading10,000-30,000DN40-DN50T
Process line500-5,000DN15-DN40T
1 000 - 20 000 кг/чDN01DN08DN15DN25DN50DN80DN150DN250
Meter range by DN and typical band for sulphuric acid. 1 000-20 000 кг/ч, логарифмическая шкала.

What to check before ordering

  1. Concentration and temperature: they define the material.
  2. Water and impurities in the line.
  3. Flow velocity: limited by corrosion on acid service.
  4. Drain and flushing before service.
  5. Ex if flammable gases are present nearby.

Materials

Available materials include 316L, 904L, C4, Hastelloy, duplex, titanium and tantalum. For sulphuric acid the final choice is made by an engineer against the corrosion table for the specific concentration and temperature: the same grade may suit 20% and fail at 98%.

If the material is not confirmed for your medium, we do not quote blind: material is agreed first, configuration second.

When Coriolis is not needed

If only rough flow indication is needed, a rotameter or a magnetic meter on diluted acid may do. Coriolis is used for mass and concentration control by density.

Frequent questions

Can 316L be used on 98% acid?

At moderate temperature it is limited; hot concentrated acid needs another material. The decision depends on concentration and temperature.

How is concentration controlled?

By density and temperature. 98% acid density is 1830-1840 kg/m³; diluted acid is noticeably lower.

Is tantalum available?

Yes, tantalum is in the material list. It is more expensive and used where other materials fail.

What about seals?

Seal material is selected together with the tubes, from the same corrosion table.