With sulphuric acid you choose the material first and the meter second. 98% acid density is 1830-1840 kg/m³, which helps control concentration in line.
Concentrated 98% acid has a density of 1830-1840 kg/m³; a diluted 20-30% solution is about 1140-1220 kg/m³. Density depends strongly on concentration, so it can be used to control dilution when temperature is known.
The acid is aggressive and there is no universal material. 316L suits diluted solutions at moderate temperature, but not hot concentrated acid. For 93-98% the material is selected by concentration and temperature.
Water ingress into concentrated acid changes both concentration and corrosion rate. Piping and drain are arranged so the line does not keep residues.
| Point | Flow, kg/h | DN | Execution |
|---|---|---|---|
| Reactor dosing | 100-3,000 | DN08-DN25 | T |
| Dilution | 1,000-10,000 | DN25-DN40 | T |
| Truck loading | 10,000-30,000 | DN40-DN50 | T |
| Process line | 500-5,000 | DN15-DN40 | T |
Available materials include 316L, 904L, C4, Hastelloy, duplex, titanium and tantalum. For sulphuric acid the final choice is made by an engineer against the corrosion table for the specific concentration and temperature: the same grade may suit 20% and fail at 98%.
If the material is not confirmed for your medium, we do not quote blind: material is agreed first, configuration second.
If only rough flow indication is needed, a rotameter or a magnetic meter on diluted acid may do. Coriolis is used for mass and concentration control by density.
At moderate temperature it is limited; hot concentrated acid needs another material. The decision depends on concentration and temperature.
By density and temperature. 98% acid density is 1830-1840 kg/m³; diluted acid is noticeably lower.
Yes, tantalum is in the material list. It is more expensive and used where other materials fail.
Seal material is selected together with the tubes, from the same corrosion table.
Tell us flow, pressure, temperature and DN. We will reply with a configuration and lead time.
Open configurator Request a quoteWe will contact you shortly.
To attach a completed questionnaire, please email it to mass-expert@ame-info.ru.