Ethanol is accounted by mass and by strength. Density of a water-alcohol solution depends on concentration, so a mass meter gives flow and density for control.
Pure ethanol density is 789 kg/m³; water-alcohol solutions range from 800 to 970 kg/m³. Density and temperature can indicate strength if the solution is two-component.
Ethanol is flammable and volatile. Ex protection, earthing and tightness are required, and lines are kept under back pressure.
Ethanol dissolves many seals. Gasket material is selected for concentration.
| Point | Flow, kg/h | DN | Execution |
|---|---|---|---|
| Blending dose | 100-3,000 | DN08-DN25 | T |
| Transfer | 3,000-15,000 | DN25-DN50 | T |
| Loading | 5,000-20,000 | DN40-DN50 | T |
| Ethanol line | 100-1,000 | DN04-DN15 | T |
The meter measures mass, density and temperature. Strength needs calibration for the specific solution, but batch deviations are visible immediately.
For simple transfer without strength control a volumetric meter will do. Coriolis is used for mass and concentration control.
By density and temperature if the solution is two-component and calibrated.
Yes, ethanol is flammable.
DN15 handles 3,600 kg/h; 3 t/h is 83% of span. DN25 is calmer.
Material is selected for ethanol concentration.
Tell us flow, pressure, temperature and DN. We will reply with a configuration and lead time.
Open configurator Request a quoteWe will contact you shortly.
To attach a completed questionnaire, please email it to mass-expert@ame-info.ru.