Hypochlorite decomposes over time and releases gas. In the line this gives bubbles, and on the sensor deposits, so material, back pressure and flushing matter.
Solution density is 1200-1250 kg/m³ depending on active chlorine. It falls over time as hypochlorite decomposes.
Released gas forms bubbles and distorts measurement. The sensor goes where back pressure is maintained and there are no dead legs.
Hypochlorite attacks metals and seals. Material is selected by concentration and temperature.
| Point | Flow, kg/h | DN | Execution |
|---|---|---|---|
| Water treatment dosing | 10-1,000 | DN04-DN15 | T |
| Transfer | 500-5,000 | DN15-DN40 | T |
| Loading | 1,000-10,000 | DN25-DN40 | T |
| Membrane flushing | 100-3,000 | DN08-DN25 | T |
The list includes 316L, 904L, C4, Hastelloy, duplex and titanium. For hypochlorite the choice depends on concentration and temperature, so material is agreed before ordering.
For simple volume dosing a diaphragm pump with a simpler meter may do. Coriolis is used for mass and accurate dosing.
Hypochlorite decomposes; concentration and density change.
Bubbles distort measurement. Back pressure and no dead legs are required.
By concentration and temperature, from the list.
Yes, at small DN with mass accuracy.
Tell us flow, pressure, temperature and DN. We will reply with a configuration and lead time.