Potassium hydroxide behaves like caustic soda: it crystallises on cooling and causes stress corrosion cracking. The meter and piping are selected for concentration and temperature.
KOH solution density is 1100-1500 kg/m³ depending on concentration. Density and temperature indicate concentration.
A 50% solution crystallises when cooled, so the line is heated.
Hot concentrated solution causes stress corrosion cracking. 316L is not suitable for all regimes.
| Point | Flow, kg/h | DN | Execution |
|---|---|---|---|
| Dosing | 50-3,000 | DN04-DN25 | T |
| Dilution | 500-10,000 | DN15-DN40 | T |
| Loading | 10,000-30,000 | DN40-DN50 | T |
| Cleaning supply | 500-5,000 | DN15-DN40 | T |
Diluted solutions at moderate temperature usually allow 316L. Hot concentrated solutions need C4 or Hastelloy. The final choice is made against the corrosion table.
For cleaning supply at stable concentration a magnetic meter may do. Coriolis is used for dosing and mass accounting.
Yes, when cooled. Heating is required.
316L for diluted, C4 or Hastelloy for hot concentrated.
By density and temperature if the solution is two-component.
KOH is not flammable; Ex depends on nearby media.
Tell us flow, pressure, temperature and DN. We will reply with a configuration and lead time.