Application by medium

Coriolis flow meter for chocolate and glaze

Tempering and glazing

Chocolate mass is viscous and temperature-sensitive: it thickens on cooling and loses structure on overheating. The meter and piping are selected for temperature and viscosity, not pipe size.

Open configurator Request a quote
DN15-DN50up to 39,000 kg/h+30...+80 °Cup to 10 MPa±0.1% of mass
Straight-tube sensors Mass-EXPERT
Straight-tube sensors Mass-EXPERT

What happens with chocolate

Chocolate mass density is 1200-1300 kg/m³; viscosity is high and depends on temperature and cocoa butter content. Working range is usually 40-50 °C.

In dead zones the mass cools and solidifies. A straight-tube sensor without bends is easier to heat and flush.

Tempering needs stable temperature. The sensor goes in a heated line without long dead legs.

Typical points and sizes

Typical points and sizes
PointFlow, kg/hDNExecution
Tempering200-3,000DN15-DN25T
Glazing500-5,000DN25-DN40T
Fillings200-3,000DN15-DN25T
Moulding feed1,000-10,000DN25-DN50T
200 - 10 000 кг/чDN01DN08DN15DN25DN50DN80DN150DN250
Meter range by DN and typical band for chocolate mass. 200-10 000 кг/ч, логарифмическая шкала.

What to check before ordering

  1. Mass temperature and line heating.
  2. Viscosity at working temperature.
  3. Flushing and drain.
  4. No dead legs or pockets.
  5. Working point not below 20-30% of span.

Straight-tube sensor

L without bends heats evenly and flushes easily, with no pockets for solidified mass. Diameter is chosen with margin so viscosity does not raise pressure drop above the pump capability.

When Coriolis is not needed

For simple supply without mass accounting a gear dosing pump will do. Coriolis is used for mass, density and recipe dosing.

Frequent questions

Will the mass solidify in the sensor?

Not with heating and flushing. Straight-tube L heats more evenly.

What temperature?

Usually 40-50 °C. Execution T has margin.

Can glaze be measured?

Yes, the same viscosity and temperature task.

What about cleaning?

Drain and scheduled flushing, no dead legs.

Related pages

Size a meter for your medium

Tell us flow, pressure, temperature and DN. We will reply with a configuration and lead time.

Open configurator Request a quote
Наверх