Syrup is dense and viscous and tends to crystallise on cooling. A mass meter measures mass and density, and a straight-tube sensor is easier to heat and clean.
Syrup density is 1200-1400 kg/m³ depending on solids. Density and temperature indicate concentration if the solution is two-component.
Viscosity is high and rises sharply on cooling. The line and sensor are heated, otherwise the pump cannot move the product.
Crystallisation clogs the sensor and valves. After a stop the line is flushed with hot water.
| Point | Flow, kg/h | DN | Execution |
|---|---|---|---|
| Product dosing | 100-3,000 | DN08-DN25 | T |
| Filling | 1,000-10,000 | DN25-DN40 | T |
| Concentrate intake | 500-5,000 | DN15-DN40 | T |
| Cleaning | 1,000-10,000 | DN25-DN40 | T |
Mass does not depend on viscosity. Density in line shows concentration deviation, and at filling it catches the start of product after cleaning.
For syrup supply to a mixer without recipe accounting a volumetric meter will do. Coriolis is used for mass and concentration control.
By density and temperature if the solution is two-component.
Heating and flushing after stop are required.
DN15 handles 3,600 kg/h; 2 t/h is 55% of span.
Yes, the same viscosity and temperature task.
Tell us flow, pressure, temperature and DN. We will reply with a configuration and lead time.
Open configurator Request a quoteWe will contact you shortly.
To attach a completed questionnaire, please email it to mass-expert@ame-info.ru.